The study established that precast concrete slabs were on average 23.22% cheaper than the cast-in-place concrete elements and precast columns were averagely 21.4% less than cast-in-place concrete columns. The study established that professionals prefer th
Learn Moreb) Full scale Off Site Clay Model 1:1 as positive mold for GFRC panel system. 1.06 QUALITY ASSURANCE A. Manufacturer Qualifications: A qualified manufacturer who participates in PCI's Plant Certification Program and is designated a PCI-Certified Plant for
Learn MoreSpecifier Notes: This section covers cast stone masonry as manufactured by Continental Cast Stone companies. Cast stone masonry is a highly refined architectural precast concrete product manufactured from semi-dry, steam-cured, earth-moist concrete to sim
Learn MoreA. This Section includes glass fiber reinforced concrete (GFRC) panels, consisting of GFRC, panel frames, anchors and connection hardware. 1. GFRC panels include [wall units] [window wall units] [mullions] [column covers] [fascia units] [cornices] [soffit
Learn MoreArchitectural GFRC (Glass Fiber Reinforced Concrete) GFRC- Glass Fiber Reinforced Concrete is designed to have a surface appearance of architectural precast and cast stone, but weighing 50 to 75% less than the other two products. The strength of the produ
Learn MoreThe hospital's architectural precast concrete panels provide a safe enclosure. Customed-colored GateStone precast finishes were integral to achieving the Mediterranean design style for the new hospital. U.S. Federal Courthouse. The 413,000 square foot U.S
Learn MoreGUIDE SPECIFICATION FOR PLANT-PRECAST CONCRETE PRODUCTS PART 1: GENERAL 1.1 REFERENCES 1.2 GENERAL REQUIREMENTS 1.3 SUBMITTALS 1.3.1 Preconstruction Submittals 1.3.2 Shop Drawings 1.3.3 Precast Concrete Unit Data 1.3.4 Design Data 1.3.5 Test Reports 1.3.6
Learn MoreThe most common types of finishes available include: Smooth or off-the-form finishes show the natural look of the concrete without trying to simulate any other building product. Fine surface details and sharp arrises can be achieved. This finish is one of
Learn Morewith, stain, or adversely affect GFRC surfaces and does not impair subsequent surface or joint treatments of GFRC. B. Form Liners: Units of face design, texture, arrangement, and configuration indicated . Provide solid backing and form supports to ensure
Learn MoreDeesman Company with more than 30 years of experience in construction with precast concrete methods and construction experience of 5.000.000 m2 with industrial, residential, administrative, cultural, therapy usages as well as 1.200.000 m length in wall co
Learn MoreTo become PCI Certified, plants must demonstrate they have appropriate experience and training in manufacturing precast concrete, quality systems and procedures in place and a commitment to quality throughout their organization. Each plant is required to
Learn MorePRECAST ARCHITECTURAL CONCRETE 034500 - 5 site and remaining range sample sets at manufacturer's plant as color and texture approval reference. I. Mockups: After sample panel[and range sample] approval but before production of architectural precast concre
Learn Moreral Precast • Architectural Cast Stone • GFRC The APA Plant Certification Program addresses the differences between wet and dry cast ... duce high quality architectural precast building units that simulate natural cut ... APA standard or it does not. APA
Learn MoreThis second edition of the PCI Manual for Quality Control for Plants and Production of Glass Fiber Reinforced Con-crete Products was prepared by the GFRC Quality Control Manual Subcommittee of the PCI Glass Fiber Reinforced Concrete Panels Committee. It r
Learn MoreIn 1973, the company formed a partnership with Forest City Dillon and opened an additional plant in Irwindale, CA. This plant produced and constructed 55 modular precast concrete apartment buildings with over 7000 apartment units, wood and metal formed po
Learn MoreSECTION 3455 - GLASS FIBER REINFORCED CONCRETE (GFRC) SPECIFICATION FOR GFRC CASTINGS. 1.0 MANUFACTURER QUALIFICATIONS: Manufacturer shall have a minimum of five years successful experience in the fabrication of GFRC units of the application and type spec
Learn More523.2R-96 Guide for Precast Cellular Concrete Floor, Roof, and Wall Units. 523.3R-14 Guide for Cellular Concretes above 50 lb/ft3 (800 kg/m3) 523.4R-09 Guide for Design and Construction with Autoclaved Aerated Concrete Panels. 524R-16 Guide to Portland Ce
Learn MoreCGA Stoneworks Standard Specifications ARCHITECTURAL CAST STONE SECTION 04-72-00 1. PART 1-GENERAL 1.1. SECTION INCLUDES - Architectural Cast Stone. A. Scope - All labor, materials and equipment to provide the Cast Stone shown on architectural drawings an
Learn MoreDec 03, 2012 · C27 benefits designers, producers and end users of precast concrete products. By Gary K. Munkelt, P.E. The American Society for Testing and Materials (ASTM) is a volunteer organization that creates and publishes standards for materials, pr
Learn MoreAdvanced Cast Stone’s GFRC Standard Specifications SECTION 03490 GLASS-FIBER REINFORCED PRECAST CONCRETE PART 1 GENERAL 1.1 SECTION INCLUDES A. Plant-cast, glass-fiber-reinforced precast concrete panels. B. Embedded hardware and anchors. C. Loose connecti